Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13636945

- Product Categories
- Friendly Links
Information Name: | Xingtai Airshower manufacturers |
Published: | 2015-01-04 |
Validity: | 30 |
Specifications: | |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Xingtai Airshower manufacturers specializing in the production of Xingtai Airshower, Xingtai most professional manufacturers of air shower to welcome you to inquire. Contact: Sun Zhuanjie Tel: 0532-66616818 13012555124 Airshower six fault Airshower use is extremely broad. However, it is often faced with the failure of the six problems. First, the power switch. Typically there are four places Airshower can cut off the power supply: 1, air shower enclosure outdoor power switch; 2, air shower room cabinet control panel; 4, Airshower sides outside the box (where the power switch cut off the power to prevent emergency situations, effectively improve the safety of the staff). When the power light barrier, not anti-re-examine these four Airshower the power supply. Second, air shower when the fan is not working. When the air shower does not work, the first time to check air shower enclosure outdoor emergency switch is off, such as determining the severed hand touch, rotate the right side to let go. Third, Airshower fan invert or Airshower wind speed is small, be sure to check 380V three-phase four-wire line is reversed, there will be someone to take a good line when electrical manufacturers factory-installed general Airshower; such as anti- pick up line source Airshower, the light will lead to Airshower fan does not work or reverse Airshower wind speed decreases, weight will burn throughout Airshower circuit boards; recommends using Airshower companies do not light intended to replace wiring, due to production needs to determine if you want to move, please consult Airshower manufacturers solve. Fourth, the wind does not blow shower room shower, in addition to the above three points, the need to check inside the box Airshower emergency stop button is pressed, such as emergency stop button for color over time, the wind does not blow shower shower room; To re-press the emergency stop button can work properly. V. Airshower not auto-sensing air shower, check the bottom right corner of the box air shower room light sensing system, see the light sensitive device is installed correctly, such as light-sensitive and light-sensitive sides are relatively normal, you can auto-sensing blowing leaching. Six, when Airshower wind speed is low for some time, please check Airshower early and efficient filter is too much dust, if so, replace the filter. (Airshower Primary filter replacement generally within 1-6 months time, Airshower efficient filters typically replaced every 6-12 months |
Admin>>>
You are the 5167 visitor
Copyright © GuangDong ICP No. 10089450, Qingdao moisturizes limited electronic purification equipment All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5167 visitor
Copyright © GuangDong ICP No. 10089450, Qingdao moisturizes limited electronic purification equipment All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility